Higher-end Laboratory Benchtop Grating Spectrophotometer
Independently developed by 3nh with core technology, the TS8560 features a dual-array CMOS image sensor for high sensitivity and a broad spectral response, ensuring precise measurements. Equipped with a 10.5-inch independent rotating screen, it offers user-friendly operation. Supporting both xenon pulse and LED light sources, it delivers exceptional stability with ΔE*ab repeatability within 0.01 and inter-instrument error under 0.1.
Key Highlights
Illuminating/Viewing Geometry: Reflect D/8, Transmittance D/0; Double Array CMOS Image Sensor
Highest repeatability (ΔEab ≤0.01) and inter-instrument agreement (ΔEab ≤0.1)
Automatic measuring aperture distinguish
Automatic temperature and humidity compensation function, make the measurement data more accurate
The camera located, clearly confirm the measured area
Adopt combination full spectrum LED light source and UV light source
Color management software
Spectro TS8560 offre la massima precisione ΔE*ab 0,01 nella flotta di spettrofotometri da banco Threenh ed è progettato per un'alta efficienza e fiducia nella formulazione del colore e nel controllo della qualità. Fornisce i risultati di misura del colore di massima qualità con accordi tra strumenti leader del settore.
Queste stazionarie strumenti di colore offrono una migliore precisione, una gamma più ampia di lunghezze d'onda e capacità di analisi dei dati più sofisticate, rendendoli ideali per il controllo della qualità in laboratori e studi di progettazione.

Tecnologia provata, prestazioni senza pari
Ogni strumento fotospettrometro 3nh è costruito sul principio di spettrofotometria affidabile, che è stato raffinato nel corso di decenni. Gli ultimi modelli TS8560 sono dotati della tecnologia CMOS, basata sul metodo brevettato del sensore di immagine CMOS dual-array, progettato per fornire una stabilità di misura eccezionale e i risultati dello spettrogramma a colori più precisi al mondo.
TS8560 è un semplice da usare strumento colorimetro spettro con prestazioni avanzate, incorporando la tecnologia della lampada Xenon per una durata di vita più lunga della sorgente e costi di manutenzione inferiori.
TS8560 supporta anche due sorgenti di luce a impulso Xenon e LED. La ripetibilità di ΔE * ab è entro 0,01, e l'errore tra strumenti è entro 0,1, e le prestazioni di misura sono super stabili e precisi, rendendolo adatto per un'ampia gamma di applicazioni nell'analisi del colore e nel trasferimento di vari campioni solidi, liquidi e fluorescenti.
Lo spettrofotometro TS8560 adotta la tecnologia di sintesi D/8 (illuminazione diffusa, angolo di visione di 8 gradi) che è ampiamente applicabile nel mondo e SCI/SCE (componente speculare incluso/componente speculare escluso), che supporta la misurazione rapida simultanea SCI+SCE.

Con il pad di visualizzazione rotativo indipendente da 10,5 pollici, rendere la risposta più veloce e l'operazione è più confortevole e conveniente.

Ha alta sensibilità e ampia gamma di risposta spettrale, che può raggiungere misurazioni di alta precisione e ripetibilità.

Supporta 40+ indici di misurazione e fonti luminose D65, A, C, D50, D55, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, CWF, DLF, TL83, TL84, TPL5, U30B, U35, NBF, ID50, ID65, LED-B1, LED-B2, LED-B3, LED-B4, LED-B5, LED-BH1, LED-RGB1, LED-V1, LED-V2, LED-C2, LED-C3, LED-C5 e altre fonti luminose personalizzate. (41 fonti luminose in totale, le parti saranno raggiunte tramite software in PC), fonti luminose di osservazione multiple, soddisfano diversi requisiti di misurazione.


Liberamente commutabile tra 4 aperture di misura: φ25.4mm/15mm/8mm/4mm. Gli utenti possono anche personalizzare le aperture.

La misurazione laterale, la misurazione verso l'alto e la misurazione verso il basso (utilizzando accessori) e altri gesti vengono posizionati e misurati, magazzini trasmessi di tipo aperto, adattandosi a più campioni.

Rendere i dati di misurazione più precisi

TS8560 ha una telecamera integrata per impostare il posizionamento della posizione. Attraverso la scena in tempo reale della fotocamera, può determinare con precisione se la parte misurata dell'oggetto è il centro bersaglio, il che migliora l'efficienza e l'accuratezza della misurazione.
Gamma di lunghezza d'onda 360nm-780nm, luce a LED combinata. Includendo UV, sorgente di luce di taglio 400nm, sorgente di luce di taglio 420nm, lampada a xenon 360-780nm.

Con il software di gestione della qualità SQCX, lo spettrofotometro TS8560 è adatto per il monitoraggio della qualità e la gestione dei dati del colore in vari settori industriali. Dati la gestione del colore dell'utente, confrontare le differenze di colore, generare rapporti di prova, fornire dati di misurazione dello spazio colore multiplo e personalizzare la gestione del colore del cliente.

Hai domande o hai bisogno di ulteriori informazioni sul nostro spettrofotometro TS8560? Per farlo, compila il nostro modulo di contatto qui sotto. I nostri esperti sono disponibili per rispondere il più rapidamente possibile.
TS8560 Benchtop Grating Spectrophotometer Specification
| Model | TS8560 (LED+Pulsed Xenon) |
| Optical Geometry | Reflect: D/8 (diffused illumination, 8-degree viewing angle) ; |
| SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source ; | |
| Transmittance: D/0 (diffuse illumination: 0° viewing) ; | |
| SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source ; | |
| HAZE (ASTM D1003); | |
| Standards meet: CIE No.15, GB/T 3978,GB 2893,GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7,JIS Z8722 under condition C | |
| Characteristic | 1. It is used for accurate analysis and transmission of laboratory color. Apply in paints, inks, textiles, garments, printing and dyeing, printing etc industries for color transfer and quality control. |
| 2. 10.5 inch rotatable display pad,128G storage,camera locating | |
| 3. Instrument can be measured on the side, upward measurement, and the downward measurement (use accessories) and other gestures. | |
| 4. Open transmission warehouse, available thickness of 54mm transmitted samples. | |
| 5. Automatic temperature and humidity compensation function. | |
| 6. Built-in full spectral high life LED light source and Xenon lighting sources, testing fluorescent samples have better recognition. | |
| Integrating Sphere Size | Φ154mm |
| Light Source Device | 360nm–780nm Wavelength range ,combined LED Light. Including UV, 400nm cut-off light source, 420nmCut-off light source,360~780nm Xenon Lamp. |
| Spectrophotometric Mode | Concave Grating |
| Sensor | 256 Image Element Double Array CMOS Image Sensor |
| Wavelength Range | 360~780nm |
| Wavelength Interval | 10nm |
| Semiband Width | 5nm |
| Measured Reflectance Range | 0~200% |
| Reflectivity Resolution | 0.01 |
| Measuring Aperture | Reflective: |
| XLAV Φ25.4mm/Φ30mm LAVΦ15mm/Φ18mm MAVΦ8mm/Φ10mm SAVΦ4mm/Φ6mm | |
| Transmissive: | |
| Φ25.4mm(No limit on sample height and width, but thickness≤54mm) | |
| Remark: | |
| 1. Automatic identification of aperture switch | |
| 2. Customized Configuration caliber and lens position | |
| Specular Component | Reflectance: SCI&SCE / Transmittance: SCI&SCE |
| Color Space | CIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99 |
| Color Difference Formula | ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99, ΔE(Hunter), ΔE*CH,555 Index |
| Other Colorimetric Index | WI(ASTM E313, CIE/ISO,AATCC,Hunter, Taube,Berger Stensby) |
| YI(ASTM D1925,ASTM 313),ISO brightness,R457 | |
| MI (Metamerism Index), | |
| Staining Fastness, Color Fastness, Color Strength, Opacity, | |
| APHA/Hazen/Pt-Co Index, Gardner Index | |
| Haze,Transmission(ASTM D1003),Saybolt index, ASTM D1500 Color code, 8° Gloss,555 Index,carbon(My,dM),Color density CMYK(A,T,E,M), Tint, Color density(part function achieved via software in PC) | |
| Observer Angle | 2°/10° |
| Illuminant | D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,DLF,TL83,TL84,TPL5,U30,B,U35,NBF |
| ID50,ID65,LED-B1,LED-B2,LED-B3,LED-B4,LED-B5,LED-BH1,LED-RGB1,LED-V1,LED-V2,LED-C2,LED-C3,LED-C5, customized light source(41 light sources in total,part achieved via software in PC) | |
| Displayed Data | Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset, Color assessment, haze, liquid chromaticity |
| Measuring Time | 2.0s(Measure SCI & SCE meantime about 4s ) |
| Repeatability | Reflectance chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.01( Under LED light source, when a white calibration plate is measured 30 times at 5 second intervals after white calibration); |
| spectrum reflectance /transmission:≤0.1% | |
| Inter-instrument Error | Φ25.4mm/SCI, Within ΔE*ab 0.1 (Average for 12 BCRA Series II color tiles) |
| Dimension | L*W*H=440x248x283mm |
| Weight | Approx. 13.5kg |
| Power | AC 24V, 3A Power adapter power supply |
| Illuminant Life Span | 5 years, more than 3 million times measurements |
| Display | 10.5-inch rotatable display pad |
| Data Port | USB & Bluetooth |
| Data Storage | 64G storage, above 100000pcs |
| Language | Simplified Chinese, Traditional Chinese, English,(Optional Customized German,Russian, French ,Spanish ,Japanese, Thai, Korean, Polish, Portuguese) |
| Operating Environment | 0~40℃(32~104°F) |
| Storage Environment | -20~50℃(-4~122°F) |
| Standard Accessory | Power Adapter, User Guide, U Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 15 caliber, 8 caliber, 4 caliber,Transmissive Test Component, cuvette, 10.5-inch screen |
| Optional Accessory | Micro Aperture(4mm) transmission test clamp component, Instrument inversion components,culture dish,Film fixture |
| Notes | Test reports can be printed through a network printer connected to a PC or display pad;The specifications are subject to change without notice. |
FAQ su TS8560 Spettrofotometri da banco
Il vero colore in chimica è il colore visto in una soluzione o composto in condizioni standardizzate. Dipende dalle transizioni elettroniche nelle molecole, in particolare dall'assorbimento di una particolare lunghezza d'onda di luce, e questo dipende dalla struttura del composto.
Tecnologia di Threenh con eccellente servizio dopo la vendita, Generalmente, la nostra garanzia dello strumento dello spettrofotometro è di un anno (periodo di supporto aggiuntivo di 3 anni). All'interno del periodo di garanzia, possiamo offrire supporto tecnico e parti a parti cambiano, necessariamente, i nostri ingegneri possono andare al vostro posto per un migliore supporto. Il nostro strumento ha Dipartimento post-vendita professionale, se avete qualsiasi problema tecnico o domanda con le nostre merci benvenuto a contattarci.
SCI e SCE Ci sono due metodi di misurazione del colore. SCI significa Specular Component Include, SCE significa Specular Component Exclude.
Sotto il metodo SCE, solo la riflessione diffusa è testata ed esclude la riflessione speculare. In questo modo, il risultato del test è simile al colore dell'oggetto osservato dagli occhi umani.
Secondo il metodo SCI, sarà inclusa sia la riflessione diffusa che la riflessione speculare. In questo modo, il valore del colore è più obiettivo. Non influirà sulle condizioni ambientali.
Quando scegliamo lo strumento, dovremmo tenere conto di questi elementi.
Il colore dei prodotti chimici viene misurato utilizzando un colorimetro o uno spettrofotometro. Gli strumenti misurano la quantità di luce che viene assorbita o riflessa da una sostanza. Può essere utilizzato per determinare la concentrazione, la purezza o la conformità agli standard del prodotto.
When detecting color differences, the first factors to consider when selecting a light source include its stability, directionality, lifespan, and the effectiveness of the ultimately obtained spectral curve. The illuminant of a colorimeter is a fixed bulb, such as a tungsten lamp,LED light or a long-life xenon lamp. However, for the same color sample, the results displayed by the instrument vary under different light sources. This is because different light sources cause different absorption and reflection of light on the sample, leading to differences in how both the human eye and the instrument perceive the color.
In general, the D65 light source is used in the application of coil steel inks for construction. The D65 light source is equivalent to average daylight. Most coil steel inks for construction are used outdoors, and sunlight is regarded as the standard light source in outdoor environments. For household appliance coil steel inks, due to their usage characteristics, they are mostly used indoors. Therefore, the A standard light source is adopted for color measurement of samples based on indoor lighting conditions. The A light source is a carefully specified tungsten light source. Other light sources, such as fluorescent light sources, can be used in many types of applications. For example, some textile factories use fluorescent light sources. Therefore, a reasonable light source should be selected as the mutually recognized measurement method based on actual usage conditions and user requirements. Once agreed upon by both parties, color measurement must be conducted under the same conditions. This helps reduce unnecessary systematic errors and human errors, achieving the optimal consistency in color measurement.
The 3nh high-precision spectrophotometric colorimeter adopts a combined LED light source with long lifespan and low power consumption, which includes UV (ultraviolet) and UV-excluded options. This design can meet the color difference detection needs of different users and supports the selection of multiple light source modes.
Discuti il tuo progetto con uno dei nostri specialisti del prodotto:
0086 755 26508999Rispondiamo alle richieste di preventivo entro 1 giorno lavorativo.
service@3nh.comInvia una richiesta demo per il prodotto che ti interessa.
Ottieni una Demo