Print & Packaging Perfect Color Density for Brand Consistency
3nh YD5010 Plus Grating Spectrophotometer Densitometer with 45/0(45 ring-shaped illumination, 0 degree viewing angle), comply to standard ISO 5-4,CIE No.15. It is suitable for using in ink printing, in Film Processing, Textile Printing and Dyeing, Plastic Electronics and Other Industries for Color Measurement and Quality Control, No Complex Calibration – Just Fast, Reliable Density Readings
Key Highlights
45/0 geometrical optics structure, comply with CIE
Reflectance spectrum, CMYK density and Lab
3.5-inch TFT true-color screen, capacitive touch screen, concave grating
Ergonomic structure design
Φ2/4/8mm Optional apertures
Pinting plants process control and quality control
3nh ha lanciato il nuovo modello YD5010 Plus Grating Spectrophotometer Densitometer con 45/0 (illuminazione a forma di anello 45, angolo di visione di 0 gradi), conforme alla norma ISO 5-4, CIE No.15. È adatto per l'uso nella stampa all'inchiostro, nella lavorazione della pellicola, nella stampa tessile e nella tintura, nell'elettronica della plastica e in altre industrie per la misurazione del colore e il controllo della qualità; particolarmente adatto per la misurazione e il controllo di qualità della densità ottica e dell'ingrandimento dei punti nella stampa a inchiostro; e è in grado di personalizzare l'apertura singola Φ2mm, Φ4mm, Φ8mm.

Sotto l'illuminazione ottica geometrica 45/0 e le condizioni di prova di M O, M 1, M 2, M 3 stipulate dalla norma ISO 13655, lo strumento può misurare con precisione i dati di riflessione dei campioni. Sotto più spazi di colore, può misurare con precisione vari indici di densità di stampa, formule di differenza di colore e indici di colore e può soddisfare i test regolari dell'utente di vari parametri.
1.Perfetta combinazione del bellissimo aspetto e della struttura ergonomica;
2.Combinate sorgenti luminose a LED con lunga vita e basso consumo energetico, inclusa la luce UV;
Aperture 3.Optional: Φ2/4/8mm, adattarsi a più campioni;
4. misurare con precisione lo spettro di riflessione, la densità CMYK e il valore di laboratorio del campione;
5. hardware elettronico di alta configurazione: schermo a colori veri TFT da 3,5 pollici, schermo tattile capacitivo, retiglia concava, sensore di immagine CMOS a doppio array da 256 pixel, ecc.;
6.Due angoli di osservatore standard: 2/10, modalità di sorgente luminosa multipla e sistemi di colore;
La modalità 7.USB è ampiamente utile;
spazio di stoccaggio 8.Large-capacità, oltre 10.000 dati di prova;
9.Particolarmente adatto per il controllo del processo e il controllo di qualità degli impianti di stampa;
10. Il software del PC ha una potente espansione della funzione.
Sulla base del principio spettrofotometrico, lo spettrodensimetro acquisisce dati spettrali di oggetti all'interno della gamma di luce visibile tramite componenti hardware tra cui fonti luminose, sistemi spettroscopici e rivelatori.
Integrato con un potente software di valutazione e gestione del colore, non solo può calcolare accuratamente i parametri del colore come i valori di tristimulo, le coordinate di cromaticità e la differenza di colore, ma dispone anche di funzioni come la previsione della formulazione del colore, la generazione di grafici di controllo di qualità e il confronto e l'analisi del colore di prodotti da diversi lotti.
Con dati intuitivi, grafici e un'interfaccia di funzionamento visualizzata, soddisfa pienamente i requisiti per una gestione e un'analisi dei colori precise in settori quali: stampa, tessuti e rivestimenti.
È principalmente applicato in settori come la stampa, l'imballaggio, la pubblicità, la fotografia, i tessili, i rivestimenti e le materie plastiche, nonché in istituzioni di gestione del colore e unità di ricerca scientifica rilevanti. corrispondenza dei colori precisa e controllo di qualità.
Con l'assistenza di software di valutazione e gestione del colorePermette anche il analisi, stoccaggio e confronto di dati sul colore, la creazione di standard e database sul colore e la ricerca sulle regole di variazione dei colori in diversi media e ambienti, fornendo così soluzioni complete per la gestione del colore e l'ottimizzazione dei processi.
Contattaci oggi stesso per discutere le vostre esigenze di misurazione del colore di stampa, richiedere una dimostrazione del prodotto o personalizzare una soluzione su misura per il vostro settore. Trasformiamo la coerenza dei colori nel tuo vantaggio competitivo.
| Model | YD5010 Plus |
| Measurement Geometry | 45/0(45 ring-shaped illumination, 0 degree viewing angle); ISO 5-4,CIE No.15 |
| Features | Common spectrophotometer densitometer, apply in ink printing, in Film Processing, Textile Printing and Dyeing, Plastic Electronics and Other Industries for Color Measurement and Quality Control;especially suitable for the measurement and quality control of optical density and dot enlargement in ink printing;able to customize single aperture Φ2mm,Φ4mm,Φ8mm. |
| Light Source | Combined LED Light, UV Light |
| Spectral separation device | Concave Grating |
| Detector | 256 Image Element Double Array CMOS Image Sensor |
| Wavelength Range | 400~700nm |
| Wavelength Pitch | 10nm |
| Half Bandwidth | 10nm |
| Measurement Conditions | Compliance with ISO 13655 measurement conditions; M0 (CIE Light Soure A) M1 (CIE Light Soure D50) M2 (Excluding UV light source) M3 (M2+Polarized light filter) |
| Density Standards | ISO Status A, E, I, T |
| Density index | Density value, density difference, dot area, dot enlargement, overprint, printing characteristics, printing contrast, tone error and gray level |
| Measurement aperture | Customized one aperture:Φ2mm,Φ4mm,Φ8mm optional |
| Color Spaces | CIE LAB,XYZ,Yxy,LCh |
| Color Difference Formula | ΔE*ab,ΔE*94,ΔE*00 |
| Other Colorimetric Index | / |
| Observer Angle | 2°/10° |
| Illuminants | A,C,D50,D55,D65,D75,F2,F7,F11,F12 |
| Measurement Time | About 1.5s |
| Repeatability | Density: Within 0.01 D |
| Chromaticity value:within ΔE*ab 0.04 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) Except M3 | |
| Inter-instrument Error | Within ΔE*ab 0.2 (Average for 12 BCRA Series II color tiles) Except M3 |
| Measurement mode | Single Measurement, Average Measurement(2-99) |
| Size(L*W*H) | 184*77*105mm |
| Weight | About 600g |
| Power source | Li-ion battery. 5000 measurements within 8 hours |
| Illuminant Life Span | 5 years, more than 3 million times measurements |
| Display | 3.5-inch TFT color LCD, Capacitive Touch Screen |
| Interface | USB, |
| Data memory | 10000 pcs |
| Language | Simplified Chinese, English, Traditional Chinese |
| Working Environment | Temperature: 0~40℃; Humidity: 0~85% (No Condensation);altitude: less than 2000 m |
| Storage Environment | Temperature: -20~50℃; Humidity: 0~85% (No Condensation)) |
| Standard Accessory | Power Adapter, USB Cable, Built-in li-ion battery, User Manual, software(download from the website),White and Black Calibration Board, Protective Cover,Polarization filter box,Locating Plate |
| Optional Accessory | Micro Printer |
| Notes: The specifications are subject to change without notice. | |
The Spectroscopic Color-Densitometer combines advanced spectral sensing technology with density measurement capabilities, supporting multiple color spaces and density standards to meet rigorous industrial color management requirements.
FAQ su YD5010 Spectrodensitometer
La nostra macchina è imballata dalla scatola di legno di esportazione standard, non sarà danneggiata. Abbiamo consegnato molte macchine di prova all'estero per mare o per aria senza danni.
To use a haze meter, the device must first be calibrated and then it will display the haziness and transmittance values.
Keep light booths clean, maintain the light source lamps, readjust the calibrated light source, and ensure that dust and fingerprints do not settle on the viewing area.
Sempre un campione di pre-produzione prima della produzione di massa; Sempre ispezione finale prima della spedizione;
Un calorimetro è utilizzato per misurare il calore guadagnato o perso durante una reazione chimica o fisica. Un campione viene prelevato in un contenitore isolato e viene misurato un cambiamento di temperatura. Questo aiuta a calcolare le alterazioni nell'energia con l'equazione Q = mcΔT, dove Q è calore.
Inconsistent results from a haze meter can stem from issues like calibration, dusty haze meter optics, inadequate power supply, and improper measurement technique. If you have any questions, you can contact our Haze measurement experts
Discuti il tuo progetto con uno dei nostri specialisti del prodotto:
0086 755 26508999Rispondiamo alle richieste di preventivo entro 1 giorno lavorativo.
service@3nh.comInvia una richiesta demo per il prodotto che ti interessa.
Ottieni una Demo