Nuovo spettrofotometro multi-angolo della serie KS

Portable Horizontal Multi Angle Spectrophotometer

Multi-Angle Spectrophotometer is specially designed for accurate measurement of metallic, pearlescent, and other special-effect color products. it precisely evaluates special-effect surfaces and ensures compliance with tolerance standards, delivering repeatable and reproducible readings of sparkle, color travel, and coarseness. Widely used in automotive, plastics, cosmetics, and other industries for quality control of effect finishes.


Key Highlights

  • 3 measurement angles, easy-to-use entry-level device

  • 256-image element double-array CMOS image sensor

  • 3.5-inch LCD Capacitive Touch Screen

  • Full spectrum LED light source

  • Excellent agreement between instruments ΔE*<0.20

  • Φ23mm Measuring Aperture

  • Widely applicable to industries such as coatings, paints, automobiles, cosmetics, inks, etc

Questo Nuovo spettrofotometro multi-angolo della serie KS Gli strumenti sono certificati con
certify
1 Anni di garanzia (Periodo di sostegno aggiuntivo di 3 anni)

SPECIAL EFFECT COLORS, MEASURED

WITH PRECISION.

Multi-angle assurance, consistent colors.

measure_SPECIAL_EFFECT_COLORS

KS006 Multi-Angle Spectrophotometer is specially designed for accurate measurement of metallic, pearlescent, and other special-effect color products. Equipped with six spectral measurement angles, it precisely evaluates special-effect surfaces and ensures compliance with tolerance standards, delivering repeatable and reproducible readings of sparkle, color travel, and coarseness. Widely used in automotive, plastics, cosmetics, and other industries for quality control of effect finishes.


Product Features

l Measures special-effect materials using six measurement angles.

l Utilizes a built-in color camera to capture color, sparkle, graininess, and coarseness.

l Features a light source with a 10-year lifespan and a 256-pixel CMOS detector.

multi_angle_measure_for_effect_paint


Highlighted Capabilities

one 3-Angle Simultaneous Measurement for Precise Capture of Special Effect ColorsSimultaneous Measurement Capability: 1 receiver + 3 light sources measure three angles (45as15°/45as45°/45as110°) simultaneously, eliminating the need for multiple adjustments and tripling efficiency.

3-Angle_Simultaneous_Measurement_for_Precise_Capture_of_Special_Effect

Full-Scenario Coverage: Adapts to all types of special-effect finishes, including automotive paints, plastic components, and cosmetic packaging, accurately evaluating appearance differences from various angles.

International Standard Compliance: Meets 12 international standards such as ASTM D2244, DIN 5033, and ISO 7724, ensuring globally recognized measurement results.

two 10-Year Light Source Lifespan, Setting the Benchmark for Industrial-Grade Reliability

Exceptional Durability: Blue-enhanced full-spectrum LED light source with a lifespan of 10 years or 5 million measurements, over 3 times longer than conventional sources.

Spectral Integrity: Covers the full 400nm-700nm visible light range without specific band gaps, enhancing measurement accuracy for metallic and pearlescent colors.

Blue-enhanced_full-spectrum_LED_light_source

Low Maintenance Advantage: Eliminates frequent light source replacement, significantly reducing annual maintenance costs and supporting 24/7 continuous factory operation.

International Standards ComplianceConforms to 10+ international standards including ASTM D 2244, DIN 5033, ISO 7724, SAE J 1545, meeting global testing requirements.

ks3006_measuring_SPECIAL_EFFECT_samples

three High-Precision Measurement Powered by Concave Grating Spectroscopy and CMOS Technology

Core Hardware Configuration: Equipped with a 256-pixel dual-array CMOS detector and concave grating spectroscopy technology, it delivers higher resolution for more accurate color measurement.

256-pixel_dual-array_CMOS_detector_and_concave_grating_spectroscopy

High Repeatability: Colorimetric repeatability of 0.02 ΔEab and inter-instrument agreement of 0.2 ΔE00 ensure seamless data comparison across different factories and devices.

measure_car_SPECIAL_EFFECT

Rapid Response: Measures a single angle in just 1 second, and completes three-angle measurements in 3 seconds—outperforming traditional equipment in efficiency.


four Comprehensive Data Visualization with Barrier-Free Operation

Visual Display:Featuring a 3.5inch fullcolor touchscreen that directly displays spectral graphs, color difference values, pass/fail judgments, and color simulations.

3.5‑inch_full‑color_touchscreen

Smart Assistance:Builtin color camera preview ensures precise positioning of the measurement area, avoiding errors caused by misalignment.

precise_positioning_of_the measurement_area

Flexible Operation:Supports dual triggering via buttons or software, with multiple measurement modessingle, continuous, and averaging (199 times)to meet diverse application needs.

five Fully Compatible Color System to Meet Customized Needs Across Industries

Multiple Color Spaces: Supports 8 color spaces including CIE LAB, XYZ, LCh, and Hunter Lab, complying with industry standards in automotive, plastics, cosmetics, and more.

ms3003 Multiple Color Spaces for choose

Multiple Color Difference Formulas: Incorporates mainstream formulas such as ΔEab, ΔE94, ΔEcmc(2:1), ΔEcmc(1:1), ΔE*00, DINΔE99, ΔE DIN6175, various automotive brand-specific formulas, ΔE(Hunter), ΔE*ch, and ΔE*uv.

Multiple Observing Conditions: Over 30 illuminants (e.g., D65, A, D50) and dual observer angles (2°/10°) to accommodate testing requirements across different countries and regions.

ms3003 Multiple Observing Conditions

six Application Scenarios

Automotive Industry:

Multi‑angle color difference control for metallic paints on vehicle bodies and pearlescent paints on bumpers, ensuring color consistency across the entire vehicle.

Cosmetics Industry:

Batch‑to‑batch comparison of pearlescent effect colors (e.g., lipstick, eyeshadow), minimizing customer complaints caused by visual discrepancies.

Plastics Industry:

Measurement of special effect colors for home appliance housings and toys, guaranteeing color uniformity across different production sites.

ms3003 application in Automotive cosmetics plastics Industry



Technical parameters of KS003

Model

KS3003

Measurement Geometry

3 measurement angles (3 light sources, 1 receiver)

Measure Angle

45° Receiver: 45as15°, 45as45°, 45as110°

Compliant Standards: ASTM D 2244, E 308, E 1164, E 2194, E 2539; DIN 5033, 5036, 6174, 6175-1, 6175-2; ISO 7724, 11664-4; SAE J 1545

Application

Provide accurate and consistent color measurement for metallic, pearlescent and other complex special effect color products

Light Source

Full spectrum LED light source with blue enhancement

Lamp Life

5 years, 3 million times measurements

Spectrophotometric Mode

Concave Grating

Sensor

256 Image Element Double Array CMOS Image Sensor

Wavelength Range

400nm-700nm

Wavelength Interval

10nm

Measurement Range

0~600%

Semiband Width

10nm

Measuring Aperture

Illumination size Φ23mm / Measuring spot 9X12mm (Customized: Illumination size Φ10mm / Measuring spot 6X8mm)

Color Space

CIE LAB,XYZ,Yxy,LCh,βxy,DIN Lab99

Color Difference Formula

ΔEab, ΔE94, ΔEcmc(2:1), ΔEcmc(1:1), ΔE00, DINΔE99, ΔE DIN6175, Various Automotive Brand Color Difference Formulas, ΔE(Hunter), ΔEch, ΔE*uv

Other Colorimetric Index

Flop Index, Int-Em

Observer Angle

2°/10°

Illuminant

D65,A,C,D50,D55,D75,F1,F2(CWF),F3,F4F5F6,F7(DLF),F8,F9F10(TPL5),F11(TL84),F12(TL83/U30),B,U35,NBF,
ID50,ID65,LED-B1,LED-B2,LED-B3,LED-B4,LED-B5,LED-BH1,LED-RGB1,LED-V1,LED-V2,LED-C2,LED-C3,LED-C5

Display

Spectral Graph/Data, Sample Colorimetric Values, Color Difference Values/Graph, Pass/Fail Results, Color Simulation

Measuring Time

Approx. 1 second for one angle
Approx. 12 seconds for all angles

Repeatability

Spectral reflectance:  Standard deviation within 0.08%
Chromaticity value:  ΔE*ab 0.02 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)

Reproducibility

ΔE*<0.10,avg on the gray tile of BCRA tile set
ΔE*<0.25,avg on the color BCRA tile set

Inter-instrument Error

0.2ΔE*00(avg on reference Series II BCRA tile set)

Effect Parameters

/

Effect Measurement

/

Effect Repeatability

/

Effect Reproducibility

/

Trigger mode

button trigger, software trigger

Measuring Mode

Single measurement, average measurement (1-99), continuous measurement (1-99)

Locating Mode

Color camera preview

Dimension

L*W*H=195X83X128mm

Weight

About 1Kg

Power

lithium-ion battery, 3.7V,5000mAh, Continuous test 5000 times within 8 hours of full charge

Display

3.5-inch TFT color LCD, Capacitive Touch Screen 

Interface

USB, Bluetooth 

Data Storage

1000 pcs Standards,10000 pcs Samples

Language

Simplified Chinese, Traditional Chinese, English, Russian

Operating Environment

10℃ to 50℃, humidity does not exceed 85%, no condensation

Storage Environment

-20℃ to 50℃, humidity does not exceed 85%, no condensation

Calibration

Built-in white board parameters, external white board,black cavity

Calibration Interval

4 hours,8 hours,24 hours,Startup calibration

Standard accessories

Power adapter, data cable, user manual, quality management software , calibration box, black calibration tile, protective

cover, wrist strap (Software Download Address:http://www.gandongdian.com/download/ ).

Optional Accessory

Micro-printer

 

Technical parameters of KS006

Model

KS006

Measurement Geometry

6 measurement angles (8 illumination sources, 1 receivers)

Measure Angle

45° Receiver
45as-15°,45as15°,45as25°,45as45°,45as75°,45as110°
Conform to the standardsASTM D 2244,E 308,E 1164,E 2194, E2539,DIN 5033,5036,6174,6175-1,6175-2;ISO 7724, 11664-4  
SAE J 1545

Application

Provide accurate and consistent color measurement for metallic, pearlescent and other complex special effect color products

Light Source

Full spectrum LED light source with blue enhancement

Lamp Life

5 years, 3 million times measurements

Spectrophotometric Mode

Concave Grating

Sensor

256 Image Element Double Array CMOS Image Sensor

Wavelength Range

400nm-700nm

Wavelength Interval

10nm

Measurement Range

0~600%

Semiband Width

10nm

Measuring Aperture

Illumination size Φ23mm / Measuring spot 9X12mm (Customized: Illumination size Φ10mm / Measuring spot 6X8mm)

Color Space

CIE LAB,XYZ,Yxy,LCh,βxy,DIN Lab99

Color Difference Formula

ΔEab, ΔE94, ΔEcmc(2:1), ΔEcmc(1:1), ΔE00, DINΔE99, ΔE DIN6175, Various Automotive Brand Color Difference Formulas, ΔE(Hunter), ΔEch, ΔE*uv

Other Colorimetric Index

Flop Index, Int-Em

Observer Angle

2°/10°

Illuminant

D65,A,C,D50,D55,D75,F1,F2(CWF),F3,F4F5F6,F7(DLF),F8,F9F10(TPL5),F11(TL84),F12(TL83/U30),B,U35,NBF,
ID50,ID65,LED-B1,LED-B2,LED-B3,LED-B4,LED-B5,LED-BH1,LED-RGB1,LED-V1,LED-V2,LED-C2,LED-C3,LED-C5

Display

Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset, Color simulation, Sample effect value, Effect difference value

Measuring Time

Approx. 1 second for one angle
Approx. 12 seconds for all angles

Repeatability

Spectral reflectance:  Standard deviation within 0.08%
Chromaticity value:  ΔE*ab 0.02 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)

Reproducibility

ΔE*<0.10,avg on the gray tile of BCRA tile set
ΔE*<0.25,avg on the color BCRA tile set

Inter-instrument Error

0.2ΔE*00(avg on reference Series II BCRA tile set)

Effect Parameters

Sparkle Grade(SG),Diffuse coarseness(DC) and Color Variation(CV)

Effect Measurement

6 angles Sparkle Grade(SG),Color Variation(CV):15as-45°,15as-30°,15as-15°,15as15°,15as45°,15as80°
15d Diffuse coarseness(DC)

Effect Repeatability

Sparkle Grade(SG) Short-term repeatability: 0.11% (10 times standard deviations) (When a color plate is measured 10 times at 10 second intervals after white calibration)
Diffuse coarseness(DC) Short-term repeatability:e0.08% (10 times standard deviations) (When a color plate is measured 10 times at 10 second intervals after white calibration)

Effect Reproducibility

Sparkle Grade(SG) Reproducibility: 1.8% (10 times standard deviations)
(avg on reference Series II BCRA tile set)
Diffuse coarseness(DC) Reproducibility: 1.3% (10 times standard deviations)(avg on reference Series II BCRA tile set)

Trigger mode

button trigger, software trigger

Measuring Mode

Single measurement, average measurement (1-99), continuous measurement (1-99)

Locating Mode

Color camera preview

Dimension

L*W*H=195X83X128mm

Weight

About 1Kg

Power

lithium-ion battery, 3.7V,5000mAh, Continuous test 5000 times within 8 hours of full charge

Display

3.5-inch TFT color LCD, Capacitive Touch Screen 

Interface

USB, Bluetooth 

Data Storage

1000 pcs Standards,10000 pcs Samples

Language

Simplified Chinese, Traditional Chinese, English, Russian

Operating Environment

10℃ to 50℃, humidity does not exceed 85%, no condensation

Storage Environment

-20℃ to 50℃, humidity does not exceed 85%, no condensation

Calibration

Built-in white board parameters, external white board,black cavity

Calibration Interval

4 hours,8 hours,24 hours,Startup calibration

Standard accessories

Power Adapter, USB Cable, User Guide,PC Software(Software Download Address:http://www.gandongdian.com/download/), Calibration Board, black light trap,Protective cap, wristband

Optional Accessory

Micro-printer

Technical parameters of KS012

Model

KS012

Measurement Geometry

12 measurement angles (8 illumination sources, 2 receivers)

Measure Angle

45° Receiver
45as-15°,45as15°,45as25°,45as45°,45as75°,45as110°
15°Receiver
15as-45°,15as-15°,15as15°,15as-30°,15as45°,15as80°
Conform to the standardsASTM D 2244,E 308,E 1164,E 2194, E2539,DIN 5033,5036,6174,6175-1,6175-2;ISO 7724, 11664-4  
SAE J 1545

Application

Provide accurate and consistent color measurement for metallic, pearlescent and other complex special effect color products

Light Source

Full spectrum LED light source with blue enhancement

Lamp Life

5 years, 3 million times measurements

Spectrophotometric Mode

Concave Grating

Sensor

256 Image Element Double Array CMOS Image Sensor

Wavelength Range

400nm-700nm

Wavelength Interval

10nm

Measurement Range

0~600%

Semiband Width

10nm

Measuring Aperture

Illumination size Φ23mm / Measuring spot 9X12mm (Customized: Illumination size Φ10mm / Measuring spot 6X8mm)

Color Space

CIE LAB,XYZ,Yxy,LCh,βxy,DIN Lab99

Color Difference Formula

ΔEab, ΔE94, ΔEcmc(2:1), ΔEcmc(1:1), ΔE00, DINΔE99, ΔE DIN6175, Various Automotive Brand Color Difference Formulas, ΔE(Hunter), ΔEch, ΔE*uv

Other Colorimetric Index

Flop Index, Int-Em

Observer Angle

2°/10°

Illuminant

D65,A,C,D50,D55,D75,F1,F2(CWF),F3,F4F5F6,F7(DLF),F8,F9F10(TPL5),F11(TL84),F12(TL83/U30),B,U35,NBF,
ID50,ID65,LED-B1,LED-B2,LED-B3,LED-B4,LED-B5,LED-BH1,LED-RGB1,LED-V1,LED-V2,LED-C2,LED-C3,LED-C5

Display

Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset, Color simulation, Sample effect value, Effect difference value

Measuring Time

Approx. 1 second for one angle
Approx. 12 seconds for all angles

Repeatability

Spectral reflectance:  Standard deviation within 0.08%
Chromaticity value:  ΔE*ab 0.02 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)

Reproducibility

ΔE*<0.10,avg on the gray tile of BCRA tile set
ΔE*<0.25,avg on the color BCRA tile set

Inter-instrument Error

0.18ΔE*00(avg on reference Series II BCRA tile set)

Effect Parameters

Sparkle Grade(SG),Diffuse coarseness(DC) and Color Variation(CV)

Effect Measurement

6 angles Sparkle Grade(SG),Color Variation(CV):15as-45°,15as-30°,15as-15°,15as15°,15as45°,15as80°
15d Diffuse coarseness(DC)

Effect Repeatability

Sparkle Grade(SG) Short-term repeatability: 0.11% (10 times standard deviations) (When a color plate is measured 10 times at 10 second intervals after white calibration)
Diffuse coarseness(DC) Short-term repeatability:e0.08% (10 times standard deviations) (When a color plate is measured 10 times at 10 second intervals after white calibration)

Effect Reproducibility

Sparkle Grade(SG) Reproducibility: 1.8% (10 times standard deviations)
(avg on reference Series II BCRA tile set)
Diffuse coarseness(DC) Reproducibility: 1.3% (10 times standard deviations)(avg on reference Series II BCRA tile set)

Trigger mode

button trigger, software trigger

Measuring Mode

Single measurement, average measurement (1-99), continuous measurement (1-99)

Locating Mode

Color camera preview

Dimension

L*W*H=195X83X128mm

Weight

About 1Kg

Power

lithium-ion battery, 3.7V,5000mAh, Continuous test 5000 times within 8 hours of full charge

Display

3.5-inch TFT color LCD, Capacitive Touch Screen 

Interface

USB, Bluetooth 

Data Storage

1000 pcs Standards,10000 pcs Samples

Language

Simplified Chinese, Traditional Chinese, English, Russian

Operating Environment

10℃ to 50℃, humidity does not exceed 85%, no condensation

Storage Environment

-20℃ to 50℃, humidity does not exceed 85%, no condensation

Calibration

Built-in white board parameters, external white board,black cavity

Calibration Interval

4 hours,8 hours,24 hours,Startup calibration

Standard accessories

Power adapter, data cable, user manual, quality management software , calibration box, black calibration tile, protective

cover, wrist strap (Software Download Address:http://www.gandongdian.com/download/ ).

Optional Accessory

Micro-printer


I nostri stimati clienti

FAQ su  Multi-angle spectrophotometer

We provide professional training to customers along with user manuals for the proper operation and maintenance of haze meters. If you have any problems during use, you can contact our experts who will quickly help you solve the problem


D/8° e 45°/0° sono due tipi di geometria di illuminazione con design di geometria ottica diverso. La geometria di illuminazione D / 8 ° è più ampiamente utilizzata per il confronto del colore e la misurazione di materiali ad alta lucidità; La geometria di illuminazione 45°/0° è utilizzata principalmente nelle industrie della stampa e dell'imballaggio.

Yes. However, for LED retrofitting to meet industry standards, color- calibrated LED modules must be used for accurate color rendering. We usually do not recommend customers to modify it themselves, as this can affect the accuracy of the color and cause unnecessary losses


Nella maggior parte del tempo, abbiamo scorte in fabbrica. Generalmente è 1-3 giorni lavorativi dopo il pagamento confermato. Dopo aver spedito, ti invieremo via email il numero di tracciamento. Puoi controllare lo stato di spedizione del tuo ordine sul sito web. Se avete bisogno urgente, possiamo considerare di fare un accordo speciale per voi.

Plastics, glasses, films, coatings, PET carboys,and packaging materials are common uses of hazemeter to monitor consistency and quality.


Use our 3nh company approved light. Replace all of the same type together and recalibrate to keep consistent color rendering. We usually do not recommend customers to modify it themselves, as this can affect the accuracy of the color and cause unnecessary losses


correlati Multi-angle spectrophotometer Ti potrebbe piacere anche

Chiamaci!

Discuti il tuo progetto con uno dei nostri specialisti del prodotto:

0086 755 26508999

Hai bisogno di prezzi?

Rispondiamo alle richieste di preventivo entro 1 giorno lavorativo.

service@3nh.com

Sai già di cosa hai bisogno?

Invia una richiesta demo per il prodotto che ti interessa.

Ottieni una Demo
Lascia il tuo messaggio
Utilizziamo i cookie per garantirti la migliore esperienza sul nostro sito. Se continui ad utilizzare questo sito, presumeremo che tu sia soddisfatto di esso. Informativa sulla privacy