Helps Enterprises Improve Product Quality
With its excellent measurement accuracy and stability, YS6010 assists enterprises in strictly controlling the color quality of products, enhancing product competitiveness, and winning market favor.7-inch TFT true color capacitive touchscreen, full light source, illumination mode: reflection D/8° and transmission D/0° (including/excluding UV measurement). It features stable color measurement and large storage capacity.
Key Highlights
256 Double Array CMOS Image Sensor
φ25.4mm/15mm/8mm/4mm 4 measuring apertures
7 inches TFT Color Capacitive Touch-screen
Built-in camera locating
PreciseLab data, used for color matching and accurate color transmission
Data storage 20000 pieces test result
Powerful extended functions at the PC software
Lo spettrofotometro da banco 3nh YS6010 è uno strumento progettato per misurare il colore e le proprietà spettrali di oggetti o sostanze. Funziona misurando e analizzando i dati sulle lunghezze d'onda della luce assorbita, trasmessa o riflessa dal campione in esame. Queste informazioni possono essere applicate in vari campi, tra cui la corrispondenza dei colori, il controllo di qualità, l'analisi dei materiali e la ricerca scientifica.
YS6010 è un strumento spettrofotometro a griglia da banco che è sviluppato da 3nh indipendentemente con proprietà intellettuale indipendente. YS6010 ha molte caratteristiche, come schermo touch capacitivo TFT da 7 pollici, illuminanti completi, geometria riflettente d / 8 e trasmissiva d / 0 (compresi o esclusi i raggi UV). Grazie alla misurazione del colore molto stabile e precisa, alla grande capacità di archiviazione e al potente software per PC, YS6010 è ideale per l'analisi del colore in ambienti di ricerca e sviluppo e di laboratorio.

Caratteristiche
1, alta configurazione dell'hardware: schermo tactile capacitivo a colori TFT da 7 pollici; Griglia concava.
2, sensore CMOS dell'elemento dell'immagine del doppio array 256; LED stabile a lunga durata, LED UV.
3, con lo spettro riflettente e trasmissivo, valore accurato del laboratorio, buono per calcolare la formula del colore e fare la trasmissione del colore precisa.
4, identifica automaticamente l'apertura di misura. Liberamente commutabile tra 4 aperture di misura: φ25.4mm/15mm/8mm/4mm. Gli utenti possono anche personalizzare le aperture.
5, sensore di temperatura integrato per monitorare e compensare la temperatura di misura per garantire la misurazione più precisione.
6, gamma di lunghezza d'onda 360nm - 780nm. Built-in 400nm cut off/460nm cut off (solo edizione della lampada a xenon), più professionale nella misurazione UV.
7, rilevatore indipendente della fonte luminosa, monitora continuamente le condizioni delle fonti luminose per garantire che la fonte luminosa sia affidabile.
8, modalità di misurazione multiple: modalità di gestione della qualità, modalità campione; Soddisfare le esigenze di più utenti.
9. Una varietà di accessori facoltativi: strumento di tenuta del campione di riflessione, impianto di trasmissione, componenti di prova di trasmissione di apertura micro 4mm, componenti di prova di inversione dello strumento, applicabili a più condizioni di lavoro;
10, archiviazione di dati di grande capacità, per il risultato della prova di 20000 pezzi.
11, localizzazione della telecamera integrata.
12, funzioni estese più potenti al software del PC.
Industria dell'applicazione
Lo spettrofotometro da banco YS6010 viene utilizzato per effettuare analisi e trasmissione precise del colore in laboratori. Può essere ampiamente applicato in diverse industrie, come la plastica, l'elettronica, la vernice e l'inchiostro, la stampa, l'abbigliamento, la pelle, la carta, l'auto, la medicina, i cosmetici, l'alimentazione, gli istituti scientifici, i laboratori.

Con la sua eccellente precisione e stabilità di misurazione, YS6010 aiuta le imprese a controllare rigorosamente la qualità del colore del prodotto, migliorando la competitività del prodotto e vincendo il favore del mercato.
YS6010 Technical Specification
| Model | YS6010 Benchtop Spectrophotometer |
| Optical Geometry | Reflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle) ; SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source Transmittance: di:0°, de:0° (diffuse illumination: 0° viewing) ; SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source; Haze(ASTM D1003), Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7 |
| Application | It is used for accurate analysis and transmission of laboratory color. Apply in paints, inks, textiles, garments, printing and dyeing, printing etc industries for color transfer and quality control. |
| Integrating Sphere Size | Φ154mm |
| Light Source | 360 nm to 780 nm, Combined LED Light, 400nm cut-off light source |
| Spectrophotometric Mode | Concave Grating |
| Sensor | 256 Image Element Double Array CMOS Image Sensor |
| Wavelength Range | 360-780nm |
| Wavelength Interval | 10nm |
| Semiband Width | 5nm |
| Measured Reflectance Range | 0-200% |
| Measuring Aperture | Reflective : Φ30mm/Φ25.4mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm; Transmissive : Φ30mm/Φ25mm; Remark: 1. Automatic identification of switch caliber 2. Customized Configuration caliber and lens position |
| Specular Component | Reflectance: SCI&SCE / Transmittance: SCI&SCE |
| Color Space | CIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99 |
| Color Difference Formula | ΔE * ab ,ΔE * uv ,ΔE * 94 ,ΔE * cmc(2:1) ,ΔE * cmc(1:1) ,ΔE * 00 , DINΔE 99 ,ΔE (Hunter), |
| Other Colorimetric Index | WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), APHA/Hazen/Pt-Co, Saybolt MI (Metamerism Index), Staining Fastness, Color Fastness, Color Strength, Opacity, 8° Glossiness,Gardner Index, 555 Index, Haze(ASTM D1003) |
| Observer Angle | 2°/10° |
| Illuminant | D65,A,C,D50,D55,D75, F1,F2,F3,F4,F5,F6, F7,F8,F9,F10,F11,F12, CWF,DLF,TL83,TL84,TPL5,U30 |
| Displayed Data | Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset |
| Measuring Time | About 2.4s (Measure SCI & SCE about 5s) |
| Repeatability | Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%) Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.02 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%) Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.03 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) |
| Inter-instrument Error | Φ25.4mm/SCI, Within ΔE*ab 0.15 |
| (Average for 12 BCRA Series II color tiles) | |
| Dimension | L*W*H=370x300x200mm |
| Weight | Approx. 9.6kg |
| Power | AC 24V, 3A Power adapter power supply |
| Illuminant Life Span | 5 years, more than 3 million times measurements |
| Display | 7-inch TFT color LCD, Capacitive Touch Screen |
| Data Port | USB & Print serial port |
| Data Storage | Standard 2000 Pcs, Sample 20000 Pcs |
| Language | Simplified Chinese, Traditional Chinese, English, |
| Operating Environment | 0~40℃, 0~85%RH (no condensing), Altitude < 2000m |
| Storage Environment | -20~50℃, 0~85%RH (no condensing) |
| Standard Accessory | Power Adapter, User Guide, CD Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 8 caliber, 4 caliber, Transmissive Test Component, Micro Aperture(4mm) transmission test clamp component, |
| Optional Accessory | Micro-printer, Micro Aperture(4mm) transmission test clamp component, Instrument inversion components, culture dish |
| Notes | The specifications are subject to change without notice. |
FAQ su YS6010 Spettrofotometri da banco
Sì, accogliamo calorosamente e invitiamo sinceramente voi o il vostro team a visitare la nostra fabbrica, aiuteremo a organizzare l'hotel e a ritirarvi dall'aeroporto.
When detecting color differences, the first factors to consider when selecting a light source include its stability, directionality, lifespan, and the effectiveness of the ultimately obtained spectral curve. The illuminant of a colorimeter is a fixed bulb, such as a tungsten lamp,LED light or a long-life xenon lamp. However, for the same color sample, the results displayed by the instrument vary under different light sources. This is because different light sources cause different absorption and reflection of light on the sample, leading to differences in how both the human eye and the instrument perceive the color.
In general, the D65 light source is used in the application of coil steel inks for construction. The D65 light source is equivalent to average daylight. Most coil steel inks for construction are used outdoors, and sunlight is regarded as the standard light source in outdoor environments. For household appliance coil steel inks, due to their usage characteristics, they are mostly used indoors. Therefore, the A standard light source is adopted for color measurement of samples based on indoor lighting conditions. The A light source is a carefully specified tungsten light source. Other light sources, such as fluorescent light sources, can be used in many types of applications. For example, some textile factories use fluorescent light sources. Therefore, a reasonable light source should be selected as the mutually recognized measurement method based on actual usage conditions and user requirements. Once agreed upon by both parties, color measurement must be conducted under the same conditions. This helps reduce unnecessary systematic errors and human errors, achieving the optimal consistency in color measurement.
The 3nh high-precision spectrophotometric colorimeter adopts a combined LED light source with long lifespan and low power consumption, which includes UV (ultraviolet) and UV-excluded options. This design can meet the color difference detection needs of different users and supports the selection of multiple light source modes.
Il colore dei prodotti chimici viene misurato utilizzando un colorimetro o uno spettrofotometro. Gli strumenti misurano la quantità di luce che viene assorbita o riflessa da una sostanza. Può essere utilizzato per determinare la concentrazione, la purezza o la conformità agli standard del prodotto.
Spettrofotometro, Colorimetro, Gloss meter, Haze meters, rivestimento spessore meter, finestra tinta meter, UV meter, Leeb durezza tester, cabina di luce, grafico di prova del colore, spessometro a ultrasuoni. La società Threenh Technology aderisce alla progettazione indipendente, alla ricerca e allo sviluppo, alla produzione e alla vendita di vari strumenti di misura.
D/8° e 45°/0° sono due tipi di geometria di illuminazione con design di geometria ottica diverso. La geometria di illuminazione D / 8 ° è più ampiamente utilizzata per il confronto del colore e la misurazione di materiali ad alta lucidità; La geometria di illuminazione 45°/0° è utilizzata principalmente nelle industrie della stampa e dell'imballaggio.
Discuti il tuo progetto con uno dei nostri specialisti del prodotto:
0086 755 26508999Rispondiamo alle richieste di preventivo entro 1 giorno lavorativo.
service@3nh.comInvia una richiesta demo per il prodotto che ti interessa.
Ottieni una Demo