YH1100 haze meter can easily achieve ASTM D1003 non-compensation method, full light transmittance,haze test.Open sample bin can be vertically and horizontally tested to accommodate more samples to be tested.The YH1100 haze meter uses a PDF array detector to meet the CIE V(λ)2 degree visual response. The compensation method can be used to measure the light transmittance and haze with high precision and repeatability.
Technical Advantage
1.Double standard ASTM
Able to meet the test standard requirements of different users, in accordance with ASTM D1003/1044,GB/T 2410,JJF 1303-2011,CIE 15.2,JIS K7105,JIS K7361,JIS K 7136
2.Easy to operate, faster and more accurate measurement
The YH1100 haze meter is equipped with a large-size touch screen for easy operation.With a PD array detector, CIE V(λ)2 degree visual response enables high precision and repeatable transmittance and fog measurements.USB data output device for docking with laboratory system.
3.Dynamic measurement
Independent light source detector and temperature sensor, constantly monitor light source and environmental change, ensure the reliability of test data.
4.Easy to measure and widely applicable to samples
Open measuring area, vertical and horizontal testing, suitable for more samples to be tested.
5.Quality control software
It provides powerful software for measuring and analyzing fog and light transmittance, which is suitable for quality monitoring and tabulated management of fog and light transmittance data in various industries.The management of users will be digitized at the PC end, the difference of fog and light transmittance will be compared, and the test report form will be generated to facilitate customer customization and management.
Application
YH1100 haze meter is widely used in glass processing, plastic processing, film processing, screen processing, packaging industry, liquid pharmaceutical analysis and other aspects.
Product Model | YH1100 Haze Meter |
Optical Geometry |
Transmittance:0/D(Parallel light illumination, diffuse viewing) Conforms to:ASTM D1003/1044,GB/T 2410,JJF 1303-2011,CIE 15.2,JIS K7105,JIS K7361,JIS K 7136 |
Character | The instrument can easily achieve ASTM D1003 non-compensation method, full light transmittance,haze test. Open measuring area for vertical and horizontal testing. In glass processing, plastic processing, film, screen processing, packaging and other industries are widely used in transmittance,haze detection. |
Integrating Sphere Size | Φ154mm |
Light Source | 400nm to 700nm, combined LED light |
Specular Component | / |
Sensor | The PD array detector satisfies CIE V(λ)2 degree visual response |
Wavelength Range | / |
Wavelength Interval | / |
Semiband Width | / |
Transmittance measurement range | 0~100% |
Measuring Aperture | Φ20mm/Φ15mm/Φ8mm/Φ4mm(Select a single aperture) |
Sample Size | Thickness <170mm |
Color Space | / |
Color Difference Formula | / |
Other Colorimetric Index | Haze(ASTM D1003/1044,ISO 13468),Transmittance T(ASTM) |
Observer Angle | 2° |
Illuminant | D65,A,C |
Displayed Data | PASS/FAIL Result |
Measuring Time | About1.5s |
Haze resolution | 0.01unit |
Haze repeatability | Φ20mm,within 0.1(After preheating and calibration of the instrument, standard deviation values of standard haze tablets with a test haze of about 40 for 30 times were taken at intervals of 5s.) |
Inter-instrument Error | Φ20mm,with 0.4(After the instrument is preheated and calibrated, the standard deviation between the standard haze tablet and the reference value is tested at an interval of 5s.) |
Dimension | L*W*H=290X211X511mm |
Weight | About7.6kg |
Power | AC 24V, 3A Power adapter power supply |
Illuminant Life Span | 5 years, more than 3 million times measurements |
Display | 7-inch TFT color LCD, Capacitive Touch Screen |
Data Port | USB & Print serial port |
Data Storage | Standard 1000 pcs,sample 20000 pcs |
Language | Simplified Chinese,Traditional Chinese,English |
Operating Environment | 0~40℃(32~104°F) |
Storage Environment | -20~50℃(-4~122°F) |
Standard Accessory | Power Adapter, User Guide,Quality Management Software (download from the official website),USB cable,0% calibration box,Aperture. |
Optional Accessory | Micro-printer,Test fixture, standard haze sheet, foot switch |
Note: | The specifications are subject to change without notice. |
With 12 rigorous quality inspection processes in place, we ensure a high yield rate of up to 98% for batch processed precision parts.
FAQs About Haze Meters
There are three measuring apertures for NH310: Φ8mm (standard accessory), Φ4mm (standard accessory), extended Φ8mm (optional accessory)
a. Turning on
b. Removing measuring aperture, install the needed measuring aperture.
c. Select "Settings-Aperture Setting" in main menu to select corresponding measuring aperture.
d. After selecting aperture, the instrument will display "White and Black Calibration" interface. White and black calibration must be performed.
e. Replace completed.
Threenh Technology with excellent after sale service, Generally, Our Spectrophotometer instrument warranty is one years(Additional support period of 3 years). Within the warranty period, we can offer technique support and parts to parts change, necessarily, our engineers may go to your place for better support. Our instrument have professional After-sales Dept, if you have any technical problem or question with our goods welcome to contact us.
Colorimeter,Gloss meter,Coating thickness meter,window tint meter,UV meter, Leeb hardness tester, Ultrasonic thickness gauge. Threenh Technology company adheres to independent design, research and development, production and sales of various measuring instruments.
Threenh Technology colorimeters provide a color deviation prompt function according to the Lab value, which can provide a reference for color matching. The handheld colorimeter can only indicate blacker, whiter, redder, greener, yellower or bluer, but it cannot provide accurate color formulas. Only with the help of a spectrophotometer and professional color matching software can fully realized automated color matching.
a. Check whether the USB cable is connected. If not, please connect it. Check whether the connection is effective. You can re-plug the USB cable to test.
b. If the USB cable is connected well but the interface still displays "USB Disconnect", please re-start the colorimeter and enter "Menu" -"Comm"to start the communication.
c. Change the USB cable or change the USB port in you PC.