YH1200 haze meter can easily achieve ASTM D1003 non-compensation method, ISO 13468 compensation method, full light transmittance,haze test.Open sample bin can be vertically and horizontally tested to accommodate more samples to be tested.The YH1200 haze meter uses a PDF array detector to meet the CIE V(λ)2 degree visual response. The compensation method can be used to measure the light transmittance and haze with high precision and repeatability.
Technical Advantage
1.Double standard ISO & ASTM
Able to meet the test standard requirements of different users, in accordance with ASTM D1003/1044,ISO 13468,ISO 14782,GB/T 2410,JJF 1303-2011,CIE 15.2,JIS K7105,JIS K7361,JIS K 7136
2.Easy to operate, faster and more accurate measurement
The YH1200 haze meter is equipped with a large-size touch screen for easy operation.With a PD array detector, CIE V(λ)2 degree visual response enables high precision and repeatable transmittance and fog measurements.USB data output device for docking with laboratory system.
3.Dynamic measurement
Independent light source detector and temperature sensor, constantly monitor light source and environmental change, ensure the reliability of test data.
4.With compensation port, so that the measurement data more accurate
Meet ASTM D1003 non-compensation method, ISO 13468 compensation method, full light transmittance, fog test, provide more accurate test results.
5.Easy to measure and widely applicable to samples
Open measuring area, vertical and horizontal testing, suitable for more samples to be tested.
6.Quality control software
It provides powerful software for measuring and analyzing fog and light transmittance, which is suitable for quality monitoring and tabulated management of fog and light transmittance data in various industries.The management of users will be digitized at the PC end, the difference of fog and light transmittance will be compared, and the test report form will be generated to facilitate customer customization and management.
Application
YH1200 haze meter is widely used in glass processing, plastic processing, film processing, screen processing, packaging industry, liquid pharmaceutical analysis and other aspects.
| Product Model | YH1200 Haze Meter |
| Optical Geometry |
Transmittance:0/D(Parallel light illumination, diffuse viewing) Conforms to:ASTM D1003/1044,ISO 14782,GB/T 2410,JJF 1303-2011,CIE 15.2,JIS K7105,JIS K7361,JIS K 7136 |
| Character | The instrument can easily achieve ASTM D1003 non-compensation method, full light transmittance,haze test. Open measuring area for vertical and horizontal testing. In glass processing, plastic processing, film, screen processing, packaging and other industries are widely used in transmittance,haze detection. |
| Integrating Sphere Size | Φ154mm |
| Light Source | 400nm to 700nm, combined LED light |
| Specular Component | / |
| Sensor | The PD array detector satisfies CIE V(λ)2 degree visual response |
| Wavelength Range | / |
| Wavelength Interval | / |
| Semiband Width | / |
| Transmittance measurement range | 0~100% |
| Measuring Aperture | Φ20mm/Φ15mm/Φ8mm/Φ4mm(Select a single aperture) |
| Sample Size | Thickness <170mm |
| Color Space | / |
| Color Difference Formula | / |
| Other Colorimetric Index | Haze(ASTM D1003/1044,ISO13468),Transmittance T(ISO),Transmittance T(ASTM) |
| Observer Angle | 2° |
| Illuminant | D65,A,C |
| Displayed Data | PASS/FAIL Result |
| Measuring Time | About1.5s |
| Haze resolution | 0.01unit |
| Haze repeatability | Φ20mm,within 0.1(After preheating and calibration of the instrument, standard deviation values of standard haze tablets with a test haze of about 40 for 30 times were taken at intervals of 5s.) |
| Inter-instrument Error | Φ20mm,with 0.4(After the instrument is preheated and calibrated, the standard deviation between the standard haze tablet and the reference value is tested at an interval of 5s.) |
| Dimension | L*W*H=290X211X511mm |
| Weight | About7.6kg |
| Power | AC 24V, 3A Power adapter power supply |
| Illuminant Life Span | 5 years, more than 3 million times measurements |
| Display | 7-inch TFT color LCD, Capacitive Touch Screen |
| Data Port | USB & Print serial port |
| Data Storage | Standard 1000 pcs,sample 20000 pcs |
| Language | Simplified Chinese,Traditional Chinese,English |
| Operating Environment | 0~40℃(32~104°F) |
| Storage Environment | -20~50℃(-4~122°F) |
| Standard Accessory | Power Adapter, User Guide,Quality Management Software (download from the official website),USB cable,0% calibration box,Aperture. |
| Optional Accessory | Micro-printer,Test fixture, standard haze sheet, foot switch |
| Note: | The specifications are subject to change without notice. |
Preguntas frecuentes sobre Medidores de niebla
Los colorímetros o espectrofotómetros se utilizan para medir el color líquido.Medir la luz que pasa o se refleja del líquido.Las lecturas se pueden informar como unidades de laboratorio*, RGB o absorbancia.Para que el análisis objetivo del color se pueda utilizar para controlar la calidad, o para medir la concentración química.
El color verdadero en química es el color visto en una solución o compuesto en condiciones estandarizadas.Depende de las transiciones electrónicas en las moléculas, específicamente la absorción de una longitud de onda particular de la luz, y esto depende de la estructura del compuesto.
El principio de la colorimetría es la ley de Beer-Lambert, que dice que la intensidad de la luz absorbida por una solución de color es proporcional a la concentración de la especie absorbente y la longitud del camino. Medir la magnitud de la luz que se absorbe a ciertas longitudes de onda.
Un medidor de brillo de pintura se utiliza para medir el nivel de brillo de pintura, por lo que refleja la luz en algunos ángulos, tales como ángulos de 20 °, 60 °, o 85 °, y mide la intensidad de esa luz. Para medir el brillo de la superficie, el nivel de brillo se compara con los estándares que se calibran y se informan en unidades de brillo (GU).
a. Los usuarios deben especificar el Nombre de Archivo Estándar, el Nombre de Archivo de Muestra y el Nombre de Archivo de Base de Datos de Muestra en el primer uso.
b.El archivo estándar se utiliza para almacenar datos de medición estándar. El archivo de muestra se utiliza para almacenar datos de medición de muestras. El archivo de base de datos de muestra se utiliza para almacenar los datos medidos exportados de registros de muestra.
Los colorimetros de tecnología Threenh proporcionan una función de señalización de desviación de color de acuerdo con el valor de laboratorio, que puede proporcionar una referencia para la coincidencia de colores. El colorimetro portátil solo puede indicar más negro, blanco, rojo, verde, amarillo o azul, pero no puede proporcionar fórmulas de color precisas. Sólo con la ayuda de un espectrofotómetro y software de coincidencia de color profesional se puede realizar totalmente la coincidencia de color automatizada.
Discúselo con uno de nuestros especialistas en productos:
0086 755 26508999Respondemos a las solicitudes de cotización dentro de 1 día hábil.
service@3nh.comEnvía una solicitud de demo para el producto que estás interesado en.
Obtén una demo